首页 | 本学科首页   官方微博 | 高级检索  
     

69.8m高冷却塔定向爆破拆除
作者单位:;1.北京科技大学;2.北京科技大学;3.北京恩菲爆破公司 北京100083;4.河北建筑科技学院
摘    要:介绍了一座双曲线钢筋混凝土筒式结构冷却塔的定向爆破拆除。阐述了冷却塔结构特点、爆破难点、总体拆除方案、设计参数的选择及飞石防护措施等。爆破取得预期效果,可为同类工程提供参考。

关 键 词:拆除爆破  筒式结构  冷却塔  飞石防护

EXPERIMENTAL STUDY ON THE EFFECTS OF BLASTING WITH CONCENTRATED AND SUB-CONCENTRATED CHARGES
Affiliation:, 3. Beijing Enfei Blasting Corp.,Beijing 100038, China)
Abstract:A large number of simulation tests for chamber blasting with concentrated or sub-concentrated charges were carried out in a site.The blasting cone and throwing-piling effect resulted from two kinds of charges were analyzed.The comparison between the tested and calculated vales of parameters such as upper- and down- broken lines and depth of the blasting cone and the maximum throwing distance for two kinds of charges was made.At the same time,the optimal spacing of sub-concentrated charges was investigated.It is concluded from the tests that the sub-concentrated charge could be used for improvement of throwing-piling effect in the construction of a dam by directional blasting and there is an optimal spacing of sub-concentrated charge favorable to throwing-piling on the condition of constant charge weight calculated by an empiric formula.
Keywords:Concentrated charge  Sub-concentrated charge  Blasting cone  Throwing-piling  Optimal spacing
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号