首页 | 本学科首页   官方微博 | 高级检索  
     

高压加热器泄漏原因分析及对策
引用本文:闫晓莉,沈旭顺,姜启凤. 高压加热器泄漏原因分析及对策[J]. 黑龙江电力, 2003, 25(4): 306-307,310
作者姓名:闫晓莉  沈旭顺  姜启凤
作者单位:1. 黑龙江省电力科学研究院,黑龙江,哈尔滨,150030
2. 大庆市给排水总公司,黑龙江,大庆,163311
3. 佳木斯发电厂,黑龙江,佳木斯,154005
摘    要:高压加热器泄漏将严重影响汽轮机组运行的经济性。以河北西柏坡发电有限责任公司1号、2号汽轮机组配套的高压加热器为例,分析了在设计、运行方面导致高压加热器泄漏的原因,提出了防止泄漏的措施和对策。

关 键 词:高压加热器 汽轮机 泄漏 分析 对策
文章编号:1002-1663(2003)04-0306-02

Causes and countermeasures for high- pressure heater leakage
YAN Xiaoli,SHEN Xushun,JIANG Qifeng. Causes and countermeasures for high- pressure heater leakage[J]. Heilongjiang Electric Power, 2003, 25(4): 306-307,310
Authors:YAN Xiaoli  SHEN Xushun  JIANG Qifeng
Abstract:High pressure heater leakage has its significant effect on the economic operation of turbine generators. Taking the high pressure heaters in connection with Nos. 1 and 2 trubine generators of Hebei Xibaipo Power Generation Co. ,Ltd as examples,the causes for high pressure heater leakage are analysed on design and operational aspects,and countermeasures are suggested for prevention of leakage.
Keywords:high pressure heater  turbine  leakage  analysis  countermeasure  