首页 | 本学科首页   官方微博 | 高级检索  
     


Visualization of oscillating flow in a double-inlet pulse tube refrigerator with a diaphragm inserted in a bypass-tube
Authors:Masao Shiraishi  Masahide Murakami
Affiliation:1. HiSIM Center, Hiroshima University, Kagamiyama 1-3-1, Higashihiroshima, Hiroshima 739-8530, Japan;2. Institute of Engineering Mechanics and Systems, University of Tsukuba, Tennoudai 1-1-1, Tsukuba, Ibaraki 305-8573, Japan;2. Department of Animal Science, Shandong Agricultural University, Taian, Shandong 271018, P. R. China;1. Laboratory for Mechanical Metallurgy, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland;2. Technical University of Catalonia, Barcelona, Spain;3. ETEL SA, Môtiers, Switzerland;1. Laboratorio de Ecología Microbiana, Departamento de Microbiología e Inmunología, Facultad de Ciencias Exactas Físico Químicas y Naturales. Universidad Nacional de Río Cuarto, Río Cuarto, Córdoba, Argentina;2. Members of the Research Career, Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Argentina
Abstract:The double-inlet pulse tube refrigerator that has a diaphragm inserted in a bypass-tube, which enabled it to transmit a pressure oscillation whereas to obstruct a DC gas flow, was manufactured and tested. The oscillating flow behavior inside of the refrigerator was studied by using a smoke-wire flow visualization technique. It was found that if the diaphragm was optimized, the performance would be improved more than that of the refrigerator with a bypass valve due to the increase in the PV work of the gas and the decrease in the convective heat loss caused by a secondary flow.
Keywords:
本文献已被 ScienceDirect 等数据库收录!