首页 | 本学科首页   官方微博 | 高级检索  
     


Three isoflurane preparations from various manufacturers. A comparison of isoflurane concentrations in fresh gas after vaporization with a Drager vaporizer type 19.3
Authors:W Wilhelm  A Hartung  R Larsen
Affiliation:Klinik für Anaesthesiologie und Intensivmedizin, Universit?tskliniken des Saarlandes, Homburg/Saar.
Abstract:OBJECTIVES: The purpose of this study was to check the precision of the Dr?ger vaporizer model 19.3 when filled with three different preparations of isoflurane. METHODS: Six Dr?ger vaporizers model 19.3 calibrated with forene were filled with forene (Abbott), isoflurane (Lilly) and isoflurane (Pharmacia); gas output was measured by infrared absorption (Irina, Dr?ger) at vaporizer settings of 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0 and 5.0 vol%, starting with a fresh gas flow of 2 1/min followed by 4, 6 and 12 1/min. Thus each of the three isoflurane preparations was checked in six different vaporizers and with four different fresh gas flows. RESULTS: Within the concentration range used in clinical practice there was no significant difference in the delivery of the three isoflurane preparations. Each of the six vaporizers produced a controllable and predictable concentration of the three preparations. CONCLUSION: Vaporizers of Dr?ger type 19.n calibrated with forene deliver the same predictable concentration of the volatile anaesthetic when filled with isoflurane from Lilly or isoflurane from Pharmacia instead of forene and may be used without impairment in patient safety. In addition, no specific calibration with one of the new isoflurane preparations is required.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号