首页 | 本学科首页   官方微博 | 高级检索  
     

水平微肋管内流动蒸发换热特性的实验研究
引用本文:吴晓敏,王晓亮,王维城. 水平微肋管内流动蒸发换热特性的实验研究[J]. 化工学报, 2003, 54(9): 1215-1219
作者姓名:吴晓敏  王晓亮  王维城
作者单位:清华大学热能工程系,北京 100084
摘    要:为了研究微肋管结构尺寸及工况等对管内流动蒸发性能的影响,对4种微肋管和1根9.52 mm光管进行了实验,4根微肋管中管外径为9.52 mm和7 mm的各2根,所用工质为R22.实验中质量流速变化范围为90~400kg•m-2•s-1,所选工况为:蒸发温度7℃,入口干度15%~20%,出口过热度5~6℃.获得了蒸发换热性能随质量流速的变化,讨论了微肋结构尺寸和管径等对蒸发换热性能的影响.两根9.52mm微肋管的传热系数比光管分别分别提高了130%和180%,而其内表面积只比光管分别增加了40%和70%.

关 键 词:微肋管  强化传热  流动蒸发  
文章编号:0438-1157(2003)09-1215-05
收稿时间:2002-04-08
修稿时间:2002-04-08

FLOW EVAPORATION HEAT TRANSFER AND PRESSURE DROP IN HORIZONTAL MICRO-FIN TUBES
WU Xiaomin,WANG Xiaoliang,WANG Weicheng. FLOW EVAPORATION HEAT TRANSFER AND PRESSURE DROP IN HORIZONTAL MICRO-FIN TUBES[J]. Journal of Chemical Industry and Engineering(China), 2003, 54(9): 1215-1219
Authors:WU Xiaomin  WANG Xiaoliang  WANG Weicheng
Abstract:To investigate the effects of micro-fin geometry and operating conditions on flow evaporation performance of micro-fin tubes, tests were conducted on four micro-fin tubes having different micro-fin geometries and one smooth tube having 9.52mm outside diameter (OD). Two of the micro-fin tubes had 9.52mm OD and the remaining two had 7.0mm OD.The refrigerant used was R22. The experiments were carried out for 90—400kg•m-2•s-1 refrigerant mass fluxes at 7℃ evaporation temperature, 15%—20% inlet vapor quality, 5—6℃ outlet superheat degrees. The variations of evaporation performance of micro-fin tubes with refrigerant mass flux were obtained. The effects of micro-fin geometry and tube diameter on performance were discussed. The two 9.52mm OD micro-fin tubes yielded 130% and 180% greater heat transfer coefficients than the smooth tube, while the inside surface areas of the two micro-fin tubes were only 40% and 70% greater than that of the smooth tube.
Keywords:micro-fin tube   heat transfer enhancement   flow evaporation  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《化工学报》浏览原始摘要信息
点击此处可从《化工学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏