390H全氢冷发电机定子接地故障的分析及处理
引用本文:姚挺生,姚卫星.390H全氢冷发电机定子接地故障的分析及处理[J].燃气轮机技术,2011,24(4):52-55.
作者姓名:姚挺生  姚卫星
作者单位:福建晋江天然气发电有限公司,福建 晋江,362251
摘    要:介绍了390H全氢冷发电机结构特点,分析了定子线圈端部接地故障的原因,采取了合理的修复措施,提出日常维护中需加强定子槽楔和铁芯紧密度的检查.

关 键 词:390H  全氢冷发电机  定子  接地故障  处理

Analysis and Solution of the Stator Grounding Failure for 390H Entire Hydrogen-cooling Generator
YAO Ting-sheng , YAO Wei-xing.Analysis and Solution of the Stator Grounding Failure for 390H Entire Hydrogen-cooling Generator[J].Gas Turbine Technology,2011,24(4):52-55.
Authors:YAO Ting-sheng  YAO Wei-xing
Affiliation:YAO Ting-sheng,YAO Wei-xing (Fujian Jinjiang Gas Power Co.,Ltd.,Fujian Jinjiang 362251,China)
Abstract:This paper introduces the structure feature of 390H entire hydrogen-cooling generator,analyzes the stator grounding failure reason at the end coil,takes reasonable repairing steps,and puts forward strengthening inspection for the stator slot wedge and core tightness in routing maintenance.
Keywords:390H entire hydrogen-cooling generator  stator  grounding failure  solution  