首页 | 本学科首页   官方微博 | 高级检索  
     


Behavior of a mechanically anchored waterproofing membrane system under wind suction and uniform Pressure
Authors:Hiroyuki Miyauchi  Nobuo Katou  Kyoji Tanaka
Affiliation:1. Chungnam National University, 305-764 Daejeon, South Korea;2. Tokyu Construction, 229-1124 Kanagawa, Japan;3. Tokyo Institute of Technology, 226-8503 Kanagawa, Japan
Abstract:A pressure and wind tunnel test was conducted to obtain the basic data for wind resistance design of a mechanically anchored waterproofing membrane system. The test specimen was a flat roof with the following dimensions: 2.4 m in width, 3 m in length and 0.29 m in height. The waterproofing material was polyvinyl chloride sheet reinforced with polyester fiber (PVC sheets). In the pressure test, because the applied pressure was equivalent to the pressure on the entire surface area of the roof, the billowing heights of the PVC sheet around the fastener had almost the same maximum values; therefore, the axial force at the fastener was also similar to the pressure induced by a compressor, and no lateral forces were measured. On the other hand, in the wind tunnel test, the strain of the PVC sheet around the fastener at windward side was larger than that of the leeward side. The lateral force was 70% of the axial force at a mean wind speed of 38.6 m/s. Therefore, it was clear that the characteristics of the mechanically anchored waterproofing membrane system in the pressure test and the wind tunnel test were different.
Keywords:Waterproofing membrane  Wind suction  Test method  Wind resistance  Force
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏