首页 | 本学科首页   官方微博 | 高级检索  
     

循环流化床锅炉水冷壁爆管原因分析及预防措施
引用本文:王伟. 循环流化床锅炉水冷壁爆管原因分析及预防措施[J]. 锅炉制造, 2008, 0(6)
作者姓名:王伟
作者单位:河南省中原大化集团公司动力厂,河南,濮阳,457004
摘    要:本文通过对循环流化床锅炉运行过程中多次发生水冷壁爆管事故的原因进行分析,提出了预防措施,改造后效果良好,从而延长了水冷壁使用寿命,提高了锅炉的运行周期,取得了良好的经济效益。

关 键 词:循环流化床锅炉  水冷壁泄漏爆管  原因分析  预防措施

Reason Analysis and Precantion on the leakage of Water Cooling Membrane of the Cycling fluidized - bed Boiler
Wang Wei. Reason Analysis and Precantion on the leakage of Water Cooling Membrane of the Cycling fluidized - bed Boiler[J]. Boiler Manufacturing, 2008, 0(6)
Authors:Wang Wei
Affiliation:Wang Wei(Zhong Yuan DaHua Group Co.Ltd of Henan province; Puyang 457004; China);
Abstract:This article gives an anlysis on the reason of leakage of water cooling membrane which happened many times during service of the cyculating fluidized bed boiler and put forward precautions.There is much improve of ter reformation.The life of water cooling membrane is made longer.Thus,a good economic efficiency is realized.
Keywords:circulating fluidized bed boiler  water cooling membrane leakage  reason analysis  precautions
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号