首页 | 本学科首页   官方微博 | 高级检索  
     


Articular cartilage volume in the knee: semiautomated determination from three-dimensional reformations of MR images
Authors:MA Piplani  DG Disler  TR McCauley  TJ Holmes  JP Cousins
Affiliation:Department of Radiology, Albany Medical College, New York 12208, USA.
Abstract:PURPOSE: To determine the accuracy of semiautomated quantification of articular cartilage volume from three-dimensional (3D) reformations of magnetic resonance (MR) images. MATERIALS AND METHODS: Sagittal, fat-suppressed, 3D, spoiled gradient-recalled-echo MR imaging of two bovine and two human cadaver knees was performed. Articular cartilage volume was calculated from 3D reformations of the MR images by using a semiautomated program written at the authors' institution. Calculated volumes were compared with directly measured volumes of the surgically removed articular cartilage. RESULTS: The percentage of error of the MR imaging-determined volumes was 6.53% +/- 4.75 (mean +/- standard deviation). A strong correlation between the two sets of observations was shown (r=.997). Linear regression showed the calculated volumes to be highly accurate (slope=1.002, P>.25). Repeated reformations yielded volumes that were reproducible (mean absolute error, 0.013 mL +/- 0.019) and not significantly different from the measured volume (P>.10). CONCLUSION: Semiautomated quantification of knee articular cartilage from MR images yields highly accurate cartilage volumes.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏