摘    要:本文将水源热泵、冰蓄冷技术和热电冷三联供技术进行了比较,分析了浙江地区气候特点、水资源状况以及水源热泵系统对水源的要求,以浙江省嘉兴市某宾馆的空调系统为实例,比较了水源热泵和冷水机组两种方式,从运行成本、维护成本、投资成本三个方面分析了水源热泵的经济性。

关 键 词:水源热泵  地表水  冷水机组

The Analysis of the Feasibility of Water Source Heat Pump Using Surface Water in Zhejiang Province
Xiang Yi,Shen Jingxia,Xu Zhihao.The Analysis of the Feasibility of Water Source Heat Pump Using Surface Water in Zhejiang Province[J].Refrigeration & Air-condition,2006,20(4):77-80.
Authors:Xiang Yi  Shen Jingxia  Xu Zhihao
Affiliation:Southwest Jiaotong University 610031
Abstract:The technics of Water Source Heat Pump, ice storage and Building ,Cooling, Heating & Power are compared in this thesis. The characteristics of climate in Zhejiang, the conditions of water source and the requires of water source to Water Source Heat Pump are analyzed. With the instance of an air condition system of a hotel in Jiaxing, Zhejiang, comparing both of Water Source Heat Pump system and chiller system, the economy of WSHP is analyzed from the three aspects of running, maintenance and investment.
Keywords:Water Source Heat Pump  Surface Water  chiller system