Mass transfer to planar and expanded metal electrodes in bubble columns |
| |
Authors: | S Piovano O N Cavatorta U Böhm |
| |
Affiliation: | (1) Departamento de Industrias, Universidad de Buenos Aires, Ciudad Universitaria, 1428 Buenos Aires, Argentina |
| |
Abstract: | Mass transfer rates at planar electrodes and electrodes of expanded metal placed in the centre of a bubble column were measured. The gas velocity and the physical properties of the electrolytic solutions were varied and different types of expanded metal were investigated. In some cases increases in the mass transfer coefficient over the planar electrode value of more than 100% were obtained. Dimensionless correlations are presented for the different systems.Nomenclature
A
mean mesh aperture
-
D
diffusivity
-
D
c
column diameter
-
g
acceleration due to gravity
-
Ga
Galileo number =gL
3/v
2
-
Gr
Grashof number =g![Delta](/content/w160215466735322/xxlarge916.gif) L
3/ v
2
-
k
mass transfer coefficient
-
L
electrode height
-
r
radial position
-
R
column radius
-
Re
Reynolds number =R
h
V
s/
-
R
h
hydraulic radius = /
-
Sc
Schmidt number = /D
-
Sh
Sherwood number =kL/D
- Vs
superficial velocity
-
gas void fraction
- M
porosity of expanded metal
-
kinematic viscosity
-
density
-
electrode area per unit volume
-
electrode area per unit net area |
| |
Keywords: | |