首页 | 本学科首页   官方微博 | 高级检索  
     

污水处理后出水中硝酸盐氮的检测及其意义
引用本文:钟永英,梁秋雪. 污水处理后出水中硝酸盐氮的检测及其意义[J]. 广东有色金属学报, 2009, 0(3)
作者姓名:钟永英  梁秋雪
作者单位:广东肇庆水务集团污水处理有限公司;
摘    要:污水处理后出水中的硝酸盐氮会通过污泥回流进入厌氧段,影响除磷效果.控制出水中硝酸盐氮的含量,是保证高效除磷最好的方法.利用紫外分光光度法可方便、快捷地测定硝酸盐氮含量.测定值和标准样品真实含量之间的相对偏差低于3.1%.

关 键 词:硝酸盐氮  紫外分光光度法  检测  脱氮除磷  

Nitrogen detection of nitrate and its significance in the effluent after sewage treatment
ZHONG Yong-ying,LIANG Qiu-xue. Nitrogen detection of nitrate and its significance in the effluent after sewage treatment[J]. Journal of Guangdong Non-Ferrous Metals, 2009, 0(3)
Authors:ZHONG Yong-ying  LIANG Qiu-xue
Affiliation:ZHONG Yong-ying,LIANG Qiu-xue(Guangdong Zhaoqing Water Group Sewage Treatment Co.Ltd.,Zhaoqing 526060,China)
Abstract:The nitrate nitrogen in the effluent after sewage treatment will enter the anaerobic zone through return sludge system,reducing the effectiveness of phosphorus removal.The best way to ensure the phosphorus removal efficiency is to control the content of nitrate nitrogen in the effluent.Ultraviolet spectrophotometry is a convenient and fast way for determining the content of nitrate nitrogen.By using it,the deviation between the measured value and the actual content of standard sample would be below 3.1%.
Keywords:nitrate nitrogen  ultraviolet spectrophotometry  detection  phosphorus and nitrogen removal  
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号