摘    要:气体绝缘家属封闭开关设备(简称GIS)是将断路器、隔离开关、接地开关、电流互感器、电压互感器、母线等元件组合封闭在接地的金属壳体内,充以一定压力的SF6气体作为绝缘介质和灭弧介质所组成的成套开关设备。GIS设备占地面积少,受环境的影响小,不会产生噪音和无线电干扰,运行安全可靠且维护工作量少,因而自问世以来得到了很快的发展。但由于GIS设备运行时间不是很长,运行人员和检修人员现场运行经验还不多,通过对GIS内部故障进行分析探讨,对GIS的运行维护有借鉴作用。

关 键 词:GIS  隔离开关  故障分析

Contact burning analysis of GIS disconnector
Zhu Jianwu,Zhou Baohong. Contact burning analysis of GIS disconnector[J]. Jiangxi Electric Power, 2010, 34(3): 20-21
Authors:Zhu Jianwu  Zhou Baohong
Abstract:GIS is a package switch with an earthing metal box comprising breaker,disconnector,earthing switch,current mutual inductor,voltage mutual inductor and bus,pressured SF6 as its insulator and arc-quenching medium.GIS has developed rapidly for its advantages as follows:taking small area,environment immunity,without noise and radio interference,and operation reliability.The paper analyzed GIS faults and provided reference for GIS operation and maintenance.