摘    要:详细介绍和分析珠海发电厂汽机强制冷却操作的整个过程和运行结果,并通过与其它电厂汽机强冷方法的分析比较,认为所用操作方法简便、冷却均匀、速度快,值得国内其它电厂借鉴。

关 键 词:珠海发电厂 700MW汽轮机 强制冷却 操作分析
文章编号:1007-290X(2002)02-0020-03

Operation analysis of turbine forced cooling for 700 MW units in Zhuhai Power Station
ZHONG Li jin,ZHENG Bi fen. Operation analysis of turbine forced cooling for 700 MW units in Zhuhai Power Station[J]. Guangdong Electric Power, 2002, 15(2): 20-22,34
Authors:ZHONG Li jin  ZHENG Bi fen
Abstract:In this paper, the operation process and result of turbine forced cooling in Zhuhai Power Station are introduced and analyzed. By comparison with the methods of main turbine forced cooling in other power plants, it is proved that the proposed method is feasible and effective.
Keywords:steam turbine  forced cooling  differential temperature  operation  