首页 | 本学科首页   官方微博 | 高级检索  
     

利用冷凝热再生低浓度除湿溶液的实验研究
引用本文:曾台烨,张小松,陈瑶.利用冷凝热再生低浓度除湿溶液的实验研究[J].制冷学报,2018,39(1):76-82.
作者姓名:曾台烨  张小松  陈瑶
作者单位:东南大学能源与环境学院,东南大学能源与环境学院,东南大学能源与环境学院
基金项目:国家自然科学基金(51376044)资助项目。
摘    要:为了获得系统重要运行参数对利用冷凝热实现低浓度除湿溶液再生性能的影响,本文在热泵驱动溶液除湿空调系统实验平台上,以低浓度的Li Cl水溶液作为再生盐溶液,再生量和冷凝热利用率作为再生性能的评价指标,对利用冷凝热实现溶液再生过程进行了实验研究。结果表明:空气流量、温度和溶液流量、温度的增加都有利于提高再生量。在夏季典型工况下,当溶液浓度为21.20%~24.91%时,冷凝热利用率在0.416~0.507波动,降低溶液浓度有利于提高冷凝热利用率。并根据实验数据拟合出了利用冷凝热再生除湿溶液过程中的耦合传热传质系数关联式,为后续如何在溶液再生过程中充分利用冷凝热提供了实验依据。

关 键 词:传热传质  冷凝热  低浓度除湿溶液  再生实验研究
收稿时间:2017/3/8 0:00:00

Experimental Investigation for Low-concentration Liquid Desiccant Regeneration with Utilization of Condensation Heat
Zeng Taiye,Zhang Xiaosong and Chen Yao.Experimental Investigation for Low-concentration Liquid Desiccant Regeneration with Utilization of Condensation Heat[J].Journal of Refrigeration,2018,39(1):76-82.
Authors:Zeng Taiye  Zhang Xiaosong and Chen Yao
Affiliation:School of Energy and Environment, Southeast University,School of Energy and Environment, Southeast University and School of Energy and Environment, Southeast University
Abstract:To investigate the heat and mass transfer effects on the regeneration process using condensation heat, experiments were performed in a hybrid air-conditioning system using low-concentration LiCl solution as the liquid desiccant. The regeneration rate and utilization ratio of condensation heat were regarded as evaluation criteria of regeneration performance. The effects of the important operating parameters on the system performance were analyzed experimentally. The results show that the air and solution mass flow rate and inlet temperature have a positive impact on the performance of regeneration. Under typical summer conditions, as the solution concentration increases from 21.20% to 24.91%, the utilization rate of condensation heat fluctuates between 0.416 and 0.507; the utilization rate of condensation heat would increase if the solution concentration was reduced. Finally, empirical correlations coupling the heat and mass transfer coefficients are presented. The experimental results provide reliable data for further analysis of using condensation heat efficiently for the solution regeneration process.
Keywords:heat and mass transfer  condensation heat  low concentration liquid desiccant  regeneration experimental study
本文献已被 CNKI 等数据库收录!
点击此处可从《制冷学报》浏览原始摘要信息
点击此处可从《制冷学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏