摘    要:研究了影响双预燃灯泵钛宝石激光器输出的因素,结果表明,合适的预燃电流和优质的钛宝石晶体对提高激光效率是非常重要的。

关 键 词:钛宝石激光   闪光灯泵浦   预燃
收稿时间:1998-05-25
修稿时间:1998-05-25

Experimental study on flashlamp-pumped Ti:Sapphire laser
Zhang Yongmei,Yu Yinshan. Experimental study on flashlamp-pumped Ti:Sapphire laser[J]. Laser Technology, 1999, 23(4): 241-243
Authors:Zhang Yongmei  Yu Yinshan
Abstract:The Ti:Sapphire laser is an useful in laser spectroscope,laser chemistry,laser remote sensing,lidar,etc..In order to obtain high energy output,we have been successfully developed a double simmer flashlamp pumped Ti:Sapphire laser.The experimental results show that the higher simmer current can imporve the pumping rate,and the larger diameter laser rod has higher slope efficiency.In our system,the slope efficiency of the laser is 0.346% for 10 laser rod.