摘    要:由于曝气沉砂池吸砂系统设备选型不合理,导致故障频发,严重影响了生产运行.通过分析原因,决定采用气提法取代吸砂泵,改造后运行效果良好.

关 键 词:曝气沉砂池  气提  水头损失  移动桁架

Failure Analysis and Solution of Grit Suction System of Aerated Grit Chamber
WANG Bao-liang,WANG Li,HU Xiao-shan,ZHAN Kui. Failure Analysis and Solution of Grit Suction System of Aerated Grit Chamber[J]. China Water & Wastewater, 2009, 25(12)
Authors:WANG Bao-liang  WANG Li  HU Xiao-shan  ZHAN Kui
Affiliation:WANG Bao-liang,WANG Li,HU Xiao-shan,ZHAN Kui(Yuzhouyuanheng Water Treatment Co.Ltd.,Yuzhou 461670,China)
Abstract:The unreasonable selection of equipment for grit suction system of aerated grit chamber caused frequent failures,and affected the operation seriously.Through analyzing the reason,it was decided that the grit suction pump was replaced by air lift method.After the reconstruction,the operation effect is good.
Keywords:aerated grit chamber  air lift  head loss  mobile truss  