首页 | 本学科首页   官方微博 | 高级检索  
     

直通高压管汇接头断裂原因分析
引用本文:卿辉,刘阳.直通高压管汇接头断裂原因分析[J].分析仪器,2013(6):122-125.
作者姓名:卿辉  刘阳
作者单位:四川省产品质量监督检验检测院,成都610100
摘    要:通过化学成分分析、金相组织观察、力学性能检测、宏观微观分析及断口分析,对40CrNiMoA直通高压管汇接头断裂原因进行分析。结果表明,机械加工缺陷和热处理不当是导致直通高压管汇接头断裂的主要原因。

关 键 词:40CrNiMoA直通高压管汇  失效分析  断口分析

Failure analysis of direct high pressure manifolds adapter
Qing Hui,Liu Yang.Failure analysis of direct high pressure manifolds adapter[J].Analytical Instrumentation,2013(6):122-125.
Authors:Qing Hui  Liu Yang
Affiliation:( Sichuan Institute of Product Quality Supervision & Inspection, Chengdu 610100, China)
Abstract:The failure of 40CrNiMoA high pressure manifolds adapter analyzed by chemical ,analysis , metallographic ,observation ,mechanical property test ,macro-analysis and micro-analysis ,fracture analy-sis.The results showed that mechanical defects and improper heat treatment are the main causes of fracture of direct high pressure manifolds adapter.
Keywords:40CrNiMoA high pressure manifolds  failure analysis  fracture analysis
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号