摘    要:针对《蒸发冷却空调冷水集成系统》一文,指出对于水侧蒸发冷却应该是制冷技术而不是空调技术,室内湿负荷与室外气温无关,开式蒸发冷却冷水机组在实际应用中的困难以及对比蒸发冷却与机械制冷的能耗时须全面考虑各项能耗指标等几个问题。

关 键 词:蒸发冷却  集成系统  能耗

Understanding of the article Integrated chilled water system of evaporative cooling air-conditioning
Na Kai.Understanding of the article Integrated chilled water system of evaporative cooling air-conditioning[J].Refrigeration and Air-conditioning,2011(5):122-125.
Authors:Na Kai
Affiliation:Na Kai(China Electronic Engineering Design Institute)
Abstract:Regarding the article Integrated chilled water system of evaporative cooling air-conditioning,points out a few issues:1) water-side evaporative cooling technology is refrigeration technology instead of air-conditioning technology,2) the indoor moisture load has no relationship with outdoor temperature,3) the difficulty of applying open evaporative cooling chiller into practice and need to consider all the energy consumption index when comparing evaporative cooling with mechanical refrigeration and so on.