首页 | 本学科首页   官方微博 | 高级检索  
     

75/20t行车电缆故障原因分析与处理
引用本文:蒲钰青,徐松泉,罗爱珍.75/20t行车电缆故障原因分析与处理[J].机械研究与应用,2010,23(1):98-99,101.
作者姓名:蒲钰青  徐松泉  罗爱珍
作者单位:甘肃大唐国际连城发电有限责任公司,甘肃,兰州,730332
摘    要:通过对某电厂75/20t T行车几次电缆故障的分析,结合现场实际情况提出了解决问题的方案并进行了现场改造。根据理论、实际改造和使用效果,论证了方案理论依据和实际的可行性,解决了行车存在的电缆频发故障的缺陷,为同类型设备的检修和技术改造,提供一个参考。

关 键 词:电缆  故障  分析  处理

Fault analysis of the cable and management for 75/20t travelling crane
Pu Yu-qing,Xu Song-quan,Luo Ai-zhen.Fault analysis of the cable and management for 75/20t travelling crane[J].Mechanical Research & Application,2010,23(1):98-99,101.
Authors:Pu Yu-qing  Xu Song-quan  Luo Ai-zhen
Affiliation:Gansu Datang international liancheng power Co./a>;Ltd/a>;Lanzhou Gansu 730332/a>;China
Abstract:Through the fault analysis of cable of 75/20t travelling crane happened several times in a workshop,the resolvent and reform project are provided and practised.Based on the theory,according to the true affection and the result of reforming,its theoretic basis and feasibility of such reform project are proved correctly and also improve totally the shortage for travelling crane.it may provide the better references for the technology improvement of the same kind of equipment.
Keywords:cable  fault  analysis  management  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号