首页 | 本学科首页   官方微博 | 高级检索  
     

EDI技术在锅炉补给水系统中的应用
引用本文:李军. EDI技术在锅炉补给水系统中的应用[J]. 华北电力技术, 2007, 0(3): 35-38
作者姓名:李军
作者单位:大唐国际北京高井热电厂,北京,100041
摘    要:主要介绍了锅炉补给水系统中使用的EDI装置的基本原理,对EDI运行中的水质、压力、流量、电导率、电流等参数控制进行了说明,并分析了影响ED I正常、稳定运行的因素,指出了EDI装置在锅炉补给水系统中的应用是可行的。

关 键 词:EDI  电渗析  锅炉  补给水系统
文章编号:1003-9171(2007)03-0035-04
修稿时间:2006-12-18

Application of EDI Technology in Make-up Water System of Boiler
Li Jun. Application of EDI Technology in Make-up Water System of Boiler[J]. North China Electric Power, 2007, 0(3): 35-38
Authors:Li Jun
Abstract:This paper introduces the principle on EDI devices used in the make-up water systems of boilers,and explains the control methods to the parameters in the operation of EDI system like quality of water,pressure of water,flow,electrical conductivity,current etc.The factors to influence on the normal and stable operation of EDI system are analysed.And it is pointed that the application of EDI system in the make-up water system of boiler is practicable.
Keywords:EDI  electro-endosmosis  boiler  make-up water system