首页 | 本学科首页   官方微博 | 高级检索  
     


Seismic behavior of bolted beam-to-column connections for concrete filled steel tube
Authors:Lai-Yun Wu  Lap-Loi Chung  Tung-Ju Shen
Affiliation:a Department of Civil Engineering, National Taiwan University, Taipei 10617, Taiwan
b National Center for Research on Earthquake Engineering, Taipei 10617, Taiwan
Abstract:Concrete-filled steel tubes (CFT) have the advantage of high strength, high stiffness and being constructed quickly. However, because the behavior of the beam-to-column connection for CFT is complicated and its design has not been sufficiently verified, their use has been limited.In this paper, a new design of bolted beam-to-column connections for CFT is proposed. A mechanical model is established in order to derive theoretical equations for calculating the stiffness, the yielding shear strength and the ultimate shear strength of the panel zone. Also, a series of cyclic loading experiments have been conducted. The experimental results and theoretical results are very close, which demonstrates that the bolted connections have superior seismic resistance in stiffness, strength, ductility and energy dissipation mechanisms. From the laboratory studies, even though the story angular drift reaches 7% and the plastic angular displacement reaches 5%, the structure still stands. Those results indicate that the seismic resistance exceeds those specified in Taiwan and the US.
Keywords:Seismic behavior  Bolted beam-to-column connection  Concrete filled tube (CFT)  Experimental study  Mechanical model  Panel zone
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号