首页 | 本学科首页   官方微博 | 高级检索  
     


A novel potentiometric membrane sensor for determination of Co based on 5-amino-3-methylisothiazole
Authors:Ashok Kumar    Sameena   Puja
Affiliation:

aDepartment of Chemistry, Indian Institute of Technology-Roorkee, Roorkee 247 667, India

Abstract:A new poly(vinylchloride) (PVC) membrane electrode for trace level determination of Co2+ ions has been developed based on 5-amino-3-methylisothiazole as an ionophore, o-nitrophenyloctylether as a plasticizer and oleic acid (OA) as a good lipophilic additive. The electrode exhibits a Nernstian slope of 29.5 ± 0.2 mV/decade in a linear range of 1.0 × 10−1 to 6.3 × 10−7 M for Co2+ ions. The detection limit of this electrode is 3.9 × 10−7 M. It has a fast response time of 12 s and can be used for a period of 4 months without any divergence in potentials. The proposed electrode reveals a good selectivity for Co (II) over a wide variety of other tested cations and could be used in the pH range 3.3–9.0. The electrode was successfully applied as an indicator electrode for the potentiometric titration of cobalt ions with EDTA as well as for the direct determination of Co (II) in real samples.
Keywords:Potentiometry   Co (II) ion-selective electrode   5-Amino-3-methylisothiazole   Poly(vinylchloride)membrane
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号