Technip制氢工艺多工况原料气压缩机故障原因分析及解决方案
引用本文:姜瑞文. Technip制氢工艺多工况原料气压缩机故障原因分析及解决方案[J]. 石油化工设备技术, 2021, 0(2): 62-66
作者姓名:姜瑞文
作者单位:中国石油化工集团有限公司工程部
摘    要:福建某石化企业40×103m3/h(标准状态)制氢装置的2台原料气往复压缩机(25-K-111A/B)在正常生产运行期间周期性发生设备故障,只能采用定期切换备用机交替维修的方式维持安全生产.针对上述问题,结合生产运行情况复算多工况条件下机组性能参数,分析原因并排除故障.结果表明,制氢装置在液体进料工况下长时间运行,偏离...

关 键 词:制氢  往复压缩机  曲轴  综合活塞推动力  反向角

REASON ANALYSIS ON FAILURE OF MULTI-CONDITION FEED GAS COMPRESSOR FOR HYDROGEN PRODUCTION PROCESS AND THE SOLUTION
Jiang Ruiwen. REASON ANALYSIS ON FAILURE OF MULTI-CONDITION FEED GAS COMPRESSOR FOR HYDROGEN PRODUCTION PROCESS AND THE SOLUTION[J]. Petro-Chemical Equipment Technology, 2021, 0(2): 62-66
Authors:Jiang Ruiwen
Affiliation:(Engineering Department of SINOPEC Group,Beijing,100728)
Abstract:Two feed gas reciprocating compressors(25-K-111A/B)in a 40×103Nm3/h hydrogen production plant of a petrochemical enterprise in Fujian Province has periodic equipment failures during normal production and operation,so it is only necessary to switch the standby machine for alternate maintenance regularly to maintain safe production.Aiming at the above problem,this paper analyzed the causes of the failures and eliminated the failures through recalculating the unit performance parameters under multiple working conditions in combination with the production and operation conditions.The results show that the hydrogen production unit deviated from the original designed main operating conditions after it had run for a long time under liquid feed conditions.Besides,the two multi-condition compressor units configured in the process flow couldn't meet the requirements of long-term operation under the condition of liquid feeding.During the operation of the compressor under this working condition,the key performance parameters such as the crosshead pin load reversal angle deviated from the requirements of the unit design,resulting in damage to the main components of the body.After comparison and selection,the whole machine was returned to the factory and was repaired as it was;two skid-mounted small flow compressor units were added to meet the liquid feeding conditions for hydrogen distribution.This solution not only solved the unit failure accurately,but also optimized the process flow.This case can provide reference for solving the problems of similar equipment in hydrogen production plants.
Keywords:hydrogen production  reciprocating compressor  crankshaft  integrated piston driving force  back-angle