首页 | 本学科首页   官方微博 | 高级检索  
     

电缆、光缆及金属护套材料土壤腐蚀原位测试研究
引用本文:王永红,钟泽成,文杰,李雅琴#邮电部第五研究所.电缆、光缆及金属护套材料土壤腐蚀原位测试研究[J].腐蚀科学与防护技术,1998,10(4):49-52.
作者姓名:王永红  钟泽成  文杰  李雅琴#邮电部第五研究所
作者单位:Fifth institute of Ministry of Post and Telecommunications,Chengdu 610062
摘    要:通过对直埋电缆、光缆对地绝缘电阻、对碳钢、黄铜、铅、铝的腐蚀率及土壤环境因素的原位连续测试,研究电缆、光缆及金属护套材料的土壤腐蚀规律.

关 键 词:电缆光缆  原位测试
收稿时间:1998-07-25
修稿时间:1998-07-25

IN SITU STUDIES ON SOIL CORROSION OF CABLE, OPTICAL CABLE AND METAILIC JACKET MATERIALS
WANG Yonghong,ZHONG Zecheng,WEN Jie,LI Yaqin.IN SITU STUDIES ON SOIL CORROSION OF CABLE, OPTICAL CABLE AND METAILIC JACKET MATERIALS[J].Corrosion Science and Protection Technology,1998,10(4):49-52.
Authors:WANG Yonghong  ZHONG Zecheng  WEN Jie  LI Yaqin
Abstract:Based on the in situ measurement of insulation resistance against ground of buried cable and optical cable,corrosion rate of carbon steel,brass,lead and aluminium, as well as soil environmental factors,regularities of soil corrosion have been investigated.