首页 | 本学科首页   官方微博 | 高级检索  
     

微生物型鲜牛奶时间温度指示器
引用本文:邱灵敏,张嘉帅,钱静,殷献华,苗冬冬.微生物型鲜牛奶时间温度指示器[J].包装工程,2020,41(9):67-73.
作者姓名:邱灵敏  张嘉帅  钱静  殷献华  苗冬冬
作者单位:1.江南大学,江苏 无锡 214000,1.江南大学,江苏 无锡 214000,1.江南大学,江苏 无锡 214000,2.江南大学产业技术研究院,江苏 宿迁 223800,3.蒙牛乳业宿迁有限公司,江苏 宿迁 223800
基金项目:国家重点研发计划(2018YFC1603300);江苏省苏北专项(SZ-SQ2017049)
摘    要:目的为了准确表征鲜牛奶的新鲜度,制备一种微生物型时间-温度指示器。方法选择瑞士乳杆菌菌种作为微生物基础,采用SPG膜乳化技术制备微生物微胶囊,按照微生物胶囊与固体基质的不同比例制作3种固体微生物时间-温度指示器,以色差值为变化参数研究其动力学特性,并与应用的鲜牛奶在恒温及变温条件下进行匹配试验。结果 3种不同比例时间-温度指示器的活化能与鲜牛奶的活化能差值在25 kJ/mol之内,其中当微胶囊质量与固体基质体积之比(g/mL)为1∶2时,在变温条件下两者的等效温度差值为2.1℃,TTI预测食品货架期终点的误差为3%。结论在恒温和变温等2种条件下时,制备的微生物型TTI可以精准实现鲜牛奶货架期的可视化。

关 键 词:时间温度指示器(TTI)  鲜牛奶  动力学参数  微生物  微胶囊
收稿时间:2019/7/27 0:00:00
修稿时间:2020/5/10 0:00:00

Microbial Time-temperature Indicator Applied in Fresh Milk
QIU Ling-min,ZHANG Jia-shuai,QIAN Jing,YIN Xian-hua and MIAO Dong-dong.Microbial Time-temperature Indicator Applied in Fresh Milk[J].Packaging Engineering,2020,41(9):67-73.
Authors:QIU Ling-min  ZHANG Jia-shuai  QIAN Jing  YIN Xian-hua and MIAO Dong-dong
Affiliation:1.Jiangnan University, Wuxi 214000, China,1.Jiangnan University, Wuxi 214000, China,1.Jiangnan University, Wuxi 214000, China,2.Research Institute of Industrial Technology of Jiangnan University, Suqian 223800, China and 3.Mengniu Dairy Co., Ltd. in Suqian, Suqian 223800, China
Abstract:The work aims to prepare a microbial time-temperature indicator, in order to characterize the freshness of fresh milk accurately. Microbial microcapsules were prepared by SPG membrane emulsification technology on the basis of Lactobacillus helveticus strains. Three kinds of solid microbial time-temperature indicators were made according to different proportions of microbial capsules and solid substrates. Their dynamic characteristics were studied by their color difference values. The test matching the applied fresh milk was carried out under the conditions of constant and variable temperatures. The difference of activation energy between three TTIs at different proportions and fresh milk was within 25 kJ/mol. When the ratio(g/mL) of microcapsule in mass to volume of solid matrix was 1∶2, the difference of equivalent temperature between the two indicators was 2.1 ℃ under variable temperature, and the error of TTI in predicting the end point of food shelf life was 3%. The microbial TTI prepared can accurately visualize the shelf life of fresh milk under constant and variable temperatures.
Keywords:time-temperature indicator  fresh milk  kinetic parameters  microorganism  microcapsules
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《包装工程》浏览原始摘要信息
点击此处可从《包装工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号