首页 | 本学科首页   官方微博 | 高级检索  
     

缺氧区、好氧区容积比对A2/O工艺反硝化除磷的影响
引用本文:曹雪梅,彭永臻,王淑莹.缺氧区、好氧区容积比对A2/O工艺反硝化除磷的影响[J].中国给水排水,2007,23(3):27-30.
作者姓名:曹雪梅  彭永臻  王淑莹
作者单位:1. 哈尔滨工业大学,市政环境工程学院,黑龙江,哈尔滨,150090
2. 哈尔滨工业大学,市政环境工程学院,黑龙江,哈尔滨,150090;北京工业大学,环境与能源工程学院,北京,100022
3. 北京工业大学,环境与能源工程学院,北京,100022
基金项目:国家高技术研究发展计划(863计划);国家自然科学基金
摘    要:反硝化除磷菌可以在碳源不足的条件下,通过"一碳两用"的方式同时实现反硝化脱氮和吸磷过程,有研究表明,A2/O工艺中存在反硝化除磷现象.为此以啤酒废水为处理对象,研究了缺氧区与好氧区容积比对A2/O工艺反硝化除磷的影响.试验结果表明,在缺氧区与好氧区容积比分别为0.33、0.48、0.60的条件下,A2/O系统对总氮的平均去除率分别为68.04%、79.64%和85.70%,对总磷的平均去除率分别为85.38%、90.80%和96.84%,对COD的去除率均在90%以上.此外,如果继续增大缺氧区与好氧区容积比,应适当调整内循环比,否则会由于缺氧区硝酸盐浓度不够而发生二次释磷现象.

关 键 词:A2/O工艺  反硝化除磷  容积比  啤酒废水
文章编号:1000-4602(2007)03-0027-04
修稿时间:2006年10月13

Influence of Volume Ratio of Anoxic Zone to Aerobic Zone on Denitrifying Phosphorus Removal in A2/O Process
CAO Xue-mei,PENG Yong-zhen,WANG Shu-ying.Influence of Volume Ratio of Anoxic Zone to Aerobic Zone on Denitrifying Phosphorus Removal in A2/O Process[J].China Water & Wastewater,2007,23(3):27-30.
Authors:CAO Xue-mei  PENG Yong-zhen  WANG Shu-ying
Affiliation:1. School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China; 2. School of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022, China
Abstract:Under the condition of insufficient carbon source,denitrifying phosphorus removal bacteria can utilize nitrate as the electron acceptor to take up phosphorus by single carbon source.It is confirmed that denitrifying phosphorus removal bacteria exist in A2/O process.Therefore,the influence of the volume ratios of anoxic zone to aerobic zone on denitrifying phosphorus removal in the A2/O process for treating brewery wastewater was studied.The results show that when the volume ratios of anoxic zone to aerobic zone are 0.33,0.48 and 0.60,the resulting average total nitrogen removal efficiencies are 68.04%,79.64% and 85.70%,the average phosphorus removal efficiencies are 85.38%,90.80% and 96.84%,respectively.Also,the average COD removal efficiencies under the three ratios are all higher than 90%.Therefore,when the volume ratios of anoxic zone to aerobic zone continue to be increased,internal recirculation ratio shall be adjusted,otherwise the nitrate concentration will not be enough in anoxic zone and phosphorus will be released again.
Keywords:A2/O process  denitrifying phosphorus removal  volume ratio  brewery wastewater
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号