首页 | 本学科首页   官方微博 | 高级检索  
     

合成塔出口锅炉给水换热器泄漏事故的处理及效果
引用本文:杨伟怀,胡益民. 合成塔出口锅炉给水换热器泄漏事故的处理及效果[J]. 化工进展, 2003, 22(6): 651-654
作者姓名:杨伟怀  胡益民
作者单位:中国石油化工股份有限公司巴陵分公司尿素产品部,岳阳,414003
摘    要:通过对由于合成塔出口锅炉给水换热器123-C1内漏,造成锅炉给水系统污染的问题进行分析,及时采取有效措施,达到了减少换热器泄漏量及避免锅炉给水系统污染的目的,避免了装置非计划停车。

关 键 词:合成塔 出口锅炉 给水换热器 泄漏事故处理 合成氨装置
文章编号:1000-6613(2003)06-0651-04
修稿时间:2003-02-24

Troubleshooting Measures for the Leakage of the Synthesis Tower Outlet Heat Exchanger
Yang Weihuai,Hu Yimin. Troubleshooting Measures for the Leakage of the Synthesis Tower Outlet Heat Exchanger[J]. Chemical Industry and Engineering Progress, 2003, 22(6): 651-654
Authors:Yang Weihuai  Hu Yimin
Abstract:This article illustrates that through analysis of the leakage of the synthesis tower outlet heat exchanger and consequent pollution of the feed water system of the boiler, effective measures have been taken in time to reduce the leakage of the heat exchanger and to avoid pollution of the feed water system and accidental shutdown.
Keywords:heat exchanger  leakage  measure  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号