首页 | 本学科首页   官方微博 | 高级检索  
     

真空和大气等离子喷涂镁黄长石生物活性涂层的对比研究
引用本文:易德亮,吴成铁,马旭兵,季珩,郑学斌,常江. 真空和大气等离子喷涂镁黄长石生物活性涂层的对比研究[J]. 无机材料学报, 2014, 29(2): 172-178. DOI: 10.3724/SP.J.1077.2014.13230
作者姓名:易德亮  吴成铁  马旭兵  季珩  郑学斌  常江
作者单位:(1. 中国科学院 上海硅酸盐研究所, 高性能陶瓷和超微结构国家重点实验室, 上海 200050; 2. 华东师范大学 生命科学学院, 上海 200062; 3. 中国科学院 上海硫酸盐研究所, 特种无机涂层重点实验室, 上海 200050)
基金项目:中国科学院对外合作项目(GJHZ1211);国家自然科学基金(81190132)~~
摘    要:大气喷涂法制备的镁黄长石涂层是一种具有优良生物活性的新型骨科移植体涂层材料, 但其结晶度较低, 影响涂层的化学稳定性。本研究采用真空等离子喷涂法在钛合金表面制备了高结晶度的镁黄长石涂层。与大气喷涂镁黄长石涂层相比, 真空喷涂镁黄长石涂层具有更高的磷灰石矿化能力, 在SBF中浸泡6 d后表面即沉积了一层类骨磷灰石层, 浸泡14 d后表面沉积的磷灰石层的厚度约为大气涂层的4倍。真空喷涂镁黄长石涂层的离子释放明显低于大气涂层, 显示出更高的化学稳定性。骨髓间充质干细胞在真空和大气喷涂镁黄长石涂层表面粘附和铺展良好, 在两种涂层表面的增殖速度均明显高于HA涂层。本研究表明真空等离子喷涂的镁黄长石陶瓷涂层因其显著提高的生物活性及化学稳定性, 可能更适合用作人工关节涂层材料。

关 键 词:镁黄长石涂层  真空等离子喷涂  模拟体液  骨髓间充质干细胞  
收稿时间:2013-04-25
修稿时间:2013-05-22

A Comparative Study of Vacuum and Air Plasma Sprayed Bioactive Akermanite Coating
YI De-Liang,WU Cheng-Tie,MA Xu-Bing,JI Heng,ZHENG Xue-Bin,CHANG Jiang. A Comparative Study of Vacuum and Air Plasma Sprayed Bioactive Akermanite Coating[J]. Journal of Inorganic Materials, 2014, 29(2): 172-178. DOI: 10.3724/SP.J.1077.2014.13230
Authors:YI De-Liang  WU Cheng-Tie  MA Xu-Bing  JI Heng  ZHENG Xue-Bin  CHANG Jiang
Affiliation:(1. State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China; 2. School of Life Science, East China Normal University, Shanghai 200062, China; 3. Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China)
Abstract:Air plasma-sprayed akermanite coating is a new type orthopedic implant coating material with high bonding strength and excellent bioactivity. However, its crystallinity is low which affects its chemical stability. In this study, high crystallinity akermanite coating has been prepared using vacuum plasma spray (VPS) method. VPS akermanite coating possesses improved apatite mineralization ability compared with APS coating. An apatite layer has formed on VPS akermanite coating surface after 6 d of immersion into simulated body fluid (SBF), and the thickness of apatite layer on VPS coating is 4 times thicker than that on APS akermanite coating. The ionic release of VPS coating is significantly lower than that of APS coating, showing improved chemical stability. Furthermore, bone marrow stem cells (BMSCs) adhere to and spread well on the surface of both VPS and APS akermanite coating surface without significant difference. The proliferation rate of BMSCs is significantly higher on VPS and APS akermanite coating surface than on HA coating. Our results suggest that vacuum plasma sprayed (VPS) akermanite coating is more suitable as orthopedic implant material due to its improved bioactivity and chemical stability.
Keywords:akermanite  coating  vacuum plasma spray  simulated body fluid  cell proliferation  
本文献已被 CNKI 等数据库收录!
点击此处可从《无机材料学报》浏览原始摘要信息
点击此处可从《无机材料学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号