摘    要:进行了不同联结方式三相变压器短路电流计算公式的推导,在此基础上用Excel表计算三相电流波形、合闸角对峰值电流的影响,并进行了辐向电动力动态响应的计算。

关 键 词:三相电源  短路  峰值电流  合闸角

Research on Test of Ability to Withstand Short Circuit of Transformer by Three-Phase Power Supply Method
ZHOU Guo-wei,LIU Hai. Research on Test of Ability to Withstand Short Circuit of Transformer by Three-Phase Power Supply Method[J]. Transformer, 2017, 54(3)
Authors:ZHOU Guo-wei  LIU Hai
Abstract:The calculation formula of three-phase short circuit current of three-phase transformer with different connection modes is derived.On this basis,the influence of three-phase current waveform and closing angle on peak current is calculated by Excel table.The dynamic response of amplitude-to-power is calculated.