摘    要:分析了转炉氧气流量测量中,温度压力变化对测量结果的影响。参考智能仪表的设计思路,提出了应用PLC控制系统中的软件方法,实现对氧气流量的温度压力补偿,从而提高了计量的准确性。

关 键 词:流量测量  温度压力补偿
文章编号:1000-7059(2007)04-0064-02
修稿时间:2007-03-022007-05-04

Realization of compensation of temperature and pressure for oxygen flow measurement of converter
FU Hai-tao. Realization of compensation of temperature and pressure for oxygen flow measurement of converter[J]. Metallurgical Industry Automation, 2007, 31(4): 64-65,67
Authors:FU Hai-tao
Affiliation:Machine and Power Department, Chongli Steelmaking Co Ltd,Shexian 056406, China
Abstract:Influence of temperature and pressure changes on measured results in measurement of converter oxygen flow is analyzed. Based on design thinking of intelligent instrument and software method of PLC control system, compensation of temperature and pressure in flow measurement was realized, so accuracy of measurement was improved.