A micropower fourth-order elliptical switched-capacitor low-pass filter |
| |
Abstract: | A micropower fourth-order elliptical switched-capacitor (SC) low-pass filter for biomedical applications has been designed and measured. The charge transfer error of an SC integrator using a transconductance amplifier is discussed. Also first-order noise and PSRR calculations are performed and compared with the results of simulations and measurements. The measurements show that by careful optimization of the gain bandwidth, slew rate, and gain of the amplifiers, high-performance low-power SC filters can be constructed. The cutoff frequency of the filter is 5 kHz, the ripple in the passband is 0.27 dB, and stopband rejection is 49 dB. The power consumption of the filter is 190 /spl mu/W with /spl plusmn/2.5-V power supplies. The dynamic range of the filter is 75 dB, and the total harmonic distortion over the whole passband range is below 0.25% for a 2-V/SUB pp/ input signal. The PSRR of the filter is above 40 dB at frequencies below 3 kHz. |
| |