首页 | 本学科首页   官方微博 | 高级检索  
     

供配电系统中无功补偿电容器的最佳配置
引用本文:戴崇. 供配电系统中无功补偿电容器的最佳配置[J]. 低压电器, 2010, 0(20): 37-41
作者姓名:戴崇
作者单位:安徽水利水电职业技术学院,安徽,合肥,231603
摘    要:由于配电网中不同地点的无功负荷和线路电阻不同,在不同地点装置电容器所产生的效果也不同。针对该现象研究分析后得出结论:无论是放射形配电网各配电线间,还是一条配电线各支线间,无功补偿的最佳配置条件是使各配电线(或支线)的无功经济当量趋于相等。

关 键 词:供配电系统  无功补偿  最佳配置  无功经济当量

Analysis on Best Configuration of Reactive Compensation Capacitor in Power Supply System
DAI Chong. Analysis on Best Configuration of Reactive Compensation Capacitor in Power Supply System[J]. Low Voltage Apparatus, 2010, 0(20): 37-41
Authors:DAI Chong
Affiliation:DAI Chong(Anhui Technical College of Water Resources and Hydrelectric Power,Hefei 231603,China)
Abstract:Because both reactive loads and line resistance in different places of power distribution network were different,effects produced by capacitors installed in different places were different too.A conclusion was drew that the best configuration was to make reactive power economy equivalent of each line trend to be equal,no matter radial or single line.
Keywords:power supply and distribution system  reactive compensation  best configuration  reactive power economy equivalent  