摘    要:针对原水污染严重的实际情况,开展了以臭氧、高锰酸钾和粉末活性炭的组合预氧化工艺强化生物活性炭滤池去除嗅味、CODMn、氨氮等的生产性试验.当原水的CODMn和氨氮浓度分别为7.0、3.0 mg/L时,出水浓度分别为3.0、0.5 mg/L,且出水无嗅味.同时试验结果还表明,对CODMn的去除主要发生在预氧化过程中,生物活性炭滤池主要靠生物吸附和活性炭吸附去除CODMn.

关 键 词:微污染原水  组合预氧化  臭氧  高锰酸钾  粉末活性炭  生物活性炭滤池
文章编号:1000-4602(2006)13-0026-05
收稿时间:2006-02-27
修稿时间:2006-02-27

Enhanced Biofiltration by Combined Preoxidation for Micropolluted Raw Water Treatment
QIN Qing-dong,MA Jun,ZHA Ren-guang,SHEN Li-ping,WANG Chun,ZHU Hai-tao. Enhanced Biofiltration by Combined Preoxidation for Micropolluted Raw Water Treatment[J]. China Water & Wastewater, 2006, 22(13): 26-29,33
Authors:QIN Qing-dong  MA Jun  ZHA Ren-guang  SHEN Li-ping  WANG Chun  ZHU Hai-tao
Affiliation:1. School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China; 2. Jiayuan Water Supply and Drainage Co. Ltd., Jiaxing 314000, China
Abstract:As raw water is terribly polluted,a full-scale experiment was carried out.The removals of odor,COD_(Mn) and ammonia nitrogen were enhanced by the process of combined preoxidation in biofiltration,which contains ozone,potassium permanganate and powdered activated carbon(PAC).When the concentrations of the COD_(Mn) and ammonia nitrogen in raw water are 7.0 mg/L and 3.0 mg/L respectively,their concentrations in treated water are 3.0 mg/L and 0.5 mg/L,respectively.At the same time,the results also show that COD_(Mn) is removed mainly in the progress of preoxidation,while the removal of COD_(Mn) in biofiltration depends on the adsorption of biological activated carbon.