毛细管气相色谱法测定正硅酸乙酯
引用本文:邱小梅,王蕾,陈萌.毛细管气相色谱法测定正硅酸乙酯[J].云南化工,2012(1):48-50.
作者姓名:邱小梅  王蕾  陈萌
作者单位:云南省化工研究院,云南昆明650228
摘    要:以HP-5毛细管柱为色谱柱,醋酸戊酯为内标物,采用氢火焰离子化检测器(FID),定量测定正硅酸乙酯含量。峰面积与浓度呈良好的线性关系,r=0.9999,精密度良好,回收率99.1%~101.2%。

关 键 词:毛细管气相色谱法  内标法  正硅酸乙酯

Determination of Tetraethyl Orthosilicate by Capillary Column Gas Chromatography
QIU Xiao-mei,WANG Lei,CHEN Meng.Determination of Tetraethyl Orthosilicate by Capillary Column Gas Chromatography[J].Yunnan Chemical Technology,2012(1):48-50.
Authors:QIU Xiao-mei  WANG Lei  CHEN Meng
Affiliation:(Yunnan Research Institute of Chemical Industry, Kunming 650228, China)
Abstract:Objective: To establish a method for the determination of tetraethyl orthosilicate with cap- illary column gas chromatography. Methods: Selecting amyl acetate as an internal standard, using HP-5 cap- illary column gas chromatography with FID detector to determine tetraethyl orthosilieate. Results: A better linear relation was found between the peak area and the concentration of tetraethyl orthosilicate, r = O. 9999, the precision was well, the recovery was 99.1%- 101.2%. Conclusion: This method for the determination of tetraethyl orthosilicate was simple, accurate and rapid.
Keywords:capillary column gas chromatography  internal standard method  tetraethyl orthosilicate