往复式压缩机空冷器加装保温棉提高外输气温度的实践
引用本文:李凯,徐泽辉,曹宏.往复式压缩机空冷器加装保温棉提高外输气温度的实践[J].节能,2012,31(10):68-69.
作者姓名:李凯  徐泽辉  曹宏
作者单位:中国石油塔里木油田分公司,新疆库尔勒,841000
摘    要:介绍往复式压缩机的参数和工作概况,针对冬季3台往复式压缩机组频繁停机问题,分析造成压缩机出口排气温度过低的原因;提出通过加装保温棉、控制空冷器的风量来进行改进,以达到提升压缩机的排气温度,保证机组正常运行。

关 键 词:活塞式压缩机  温度  故障分析

Analysis on factors influencing exhaust temperature low of piston compressor and its improvement
LI Kai,XU Ze-hui,CAO-Hong.Analysis on factors influencing exhaust temperature low of piston compressor and its improvement[J].Energy Conservation,2012,31(10):68-69.
Authors:LI Kai  XU Ze-hui  CAO-Hong
Affiliation:(China Petroleum Tarim Oilfield Company,Korla 841000,China)
Abstract:Introduces the structure and principle of reciprocating compressor,analyses the causes of compressor outlet temperature is too low the reason,put forward by controlling the air cooling device of air to the improvement measures,improve the compressor discharge temperature,to ensure the normal operation of the unit.
Keywords:piston compressor  temperature  fault analysis