抑制电导-离子色谱法同时测定肉制品中亚硝酸盐和硝酸盐
引用本文:姬建生,高敬铭,符锋,尹成华. 抑制电导-离子色谱法同时测定肉制品中亚硝酸盐和硝酸盐[J]. 中国食物与营养, 2010, 0(10): 50-52
作者姓名:姬建生  高敬铭  符锋  尹成华
作者单位:河南省粮油饲料产品质量监督检验站,郑州450003
摘    要:建立了一种灵敏、快速的同时测定肉制品中亚硝酸盐和硝酸盐的抑制电导-离子色谱分析方法。样品经超声提取后,以DIONEX IonPac AS19(4mm×250mm)色谱柱分离,用DIONEX EG40淋洗液发生器自动淋洗,采用梯度洗脱方式,以抑制电导检测器进行检测。实验表明,硝酸盐和亚硝酸盐的方法检出限(3S/N)为0.6mg/kg和0.8mg/kg,在0.1~50ug/ml范围内呈良好线性关系,回收率为98.4%和96.5%,重复性(RSD)为2.8%和3.2%。本方法灵敏度高,重复性好,可用于肉制品中的亚硝酸盐和硝酸盐的检测。

关 键 词:抑制电导-离子色谱法  肉制品  亚硝酸盐  硝酸盐

Simultaneous Determination of Nitrite and Nitrate in Meat Products by Suppressed Conductivity-ion Chromatography
JI Jian-sheng,GAO Jing-ming,FU Feng,YIN Cheng-hua. Simultaneous Determination of Nitrite and Nitrate in Meat Products by Suppressed Conductivity-ion Chromatography[J]. Food and Nutrition in China, 2010, 0(10): 50-52
Authors:JI Jian-sheng  GAO Jing-ming  FU Feng  YIN Cheng-hua
Affiliation:(Henan Station For Supervision and Inspection of Grain, Oil and Feed Product Quality, Zhengzhou 450003)
Abstract:A sensitive and fast analytical method based on suppressed conductivity-ion chromatography had been developed for the simultaneous determination of nitrite and nitrate in meat products. After the samples were extracted in ultrasonic wave, the ion separation was performed on a DIONEX IonPac AS19 column (4mm × 250mm) with a linear gradient elution program ,eluting by DIONEX EG40 .The anions were detected by suppressed conductivity. The results showed that the limits of detection (3S/N) for nitrite and nitrate were 0.6mg/kg and 0.8mg/kg. The calibration curves showed good linearities for nitrite and nitrate in the range of 0.1-50ug/ ml. The recovery rates were 98.4% and 96.5% with the RSD 2.8% and 3.2%. The method was sensitive,reproducible and adapted to the determination of nitrite and nitrate in meat products.
Keywords:Suppressed Conductivity-ion Chromatography  Meat Foods  Nitrite  Nitrate