多屏绝热辐射直埋蒸汽管道保温层的设计
引用本文:杨明学,高百争,杨秋. 多屏绝热辐射直埋蒸汽管道保温层的设计[J]. 煤气与热力, 2007, 27(3): 66-68
作者姓名:杨明学  高百争  杨秋
作者单位:大连科华热力管道有限公司,辽宁,大连,116113;大连科华热力管道有限公司,辽宁,大连,116113;大连科华热力管道有限公司,辽宁,大连,116113
摘    要:多屏绝热辐射直埋蒸汽管道保温层由多层屏蔽反射层与常规保温材料制成。介绍了多屏绝热辐射直埋蒸汽管道的保温层设计计算方法,与实测结果比较,相对误差较小,可满足工程设计需要。

关 键 词:直埋敷设  蒸汽管道  保温层  多屏绝热辐射
文章编号:1000-4416(2007)03-0066-03
修稿时间:2006-10-172006-11-30

Design of Insulating Layer of Multi-screen Insulated Radiant Directly Buried Steam Pipeline
YANG Ming-xue,GAO Bai-zheng,YANG Qiu. Design of Insulating Layer of Multi-screen Insulated Radiant Directly Buried Steam Pipeline[J]. Gas & Heat, 2007, 27(3): 66-68
Authors:YANG Ming-xue  GAO Bai-zheng  YANG Qiu
Affiliation:Dalian Kehua Heating Pipeline Co., Ltd., Dalian 116113, China
Abstract:The insulating layer of multi-screen insulated radiant directly buried steam pipeline is composed of multi-screens reflecting layer and conventional insulating material. The calculation method for design of insulating layer of multi-screen insulated radiant directly buried steam pipeline is introduced. Compared with the measured result, this method has less relative error and satisfies the need for engineering design.
Keywords:directly buried installation  steam pipeline  insulating layer  multi-screen insulated radiant  