首页 | 本学科首页   官方微博 | 高级检索  
     

对混凝土柱静态破碎效果的分析
引用本文:李瑞森,王英,郑文忠,姜智盛,郭常顺. 对混凝土柱静态破碎效果的分析[J]. 哈尔滨工业大学学报, 2022, 54(4): 32-42
作者姓名:李瑞森  王英  郑文忠  姜智盛  郭常顺
作者单位:结构工程灾变与控制教育部重点实验室哈尔滨工业大学,哈尔滨 150090;土木工程智能防灾减灾工业和信息化部重点实验室哈尔滨工业大学,哈尔滨 150090
基金项目:国家重点研发计划(2017YFC0806100)
摘    要:为考察混凝土强度及是否割断箍筋对柱静态破碎效果的影响,对不同强度等级的8个混凝土柱在柱顶沿柱高钻孔并注入静态破碎剂浆体,其中4个试件在孔侧面割断箍筋,使用裂缝的平均宽度之和表示试件的破碎效果.试验结果表明:试件的破碎效果随着混凝土强度的提高而降低,不割断箍筋的试件,破碎效果的降低幅度逐渐增大,割断箍筋的试件,破碎效果的...

关 键 词:静态破碎  混凝土柱  混凝土强度  割断箍筋  破碎效果
收稿时间:2021-06-04

Analysis of static crushing effect of concrete column
LI Ruisen,WANG Ying,ZHENG Wenzhong,JIANG Zhisheng,GUO Changshun. Analysis of static crushing effect of concrete column[J]. Journal of Harbin Institute of Technology, 2022, 54(4): 32-42
Authors:LI Ruisen  WANG Ying  ZHENG Wenzhong  JIANG Zhisheng  GUO Changshun
Affiliation:Key Lab of Structures Dynamic Behavior and Control Harbin Institute of Technology, Ministry of Education, Harbin 150090, China;Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters Harbin Institute of Technology, Ministry of Industry and Information Technology, Harbin 150090, China
Abstract:In order to investigate the impact of concrete strength and whether the stirrups are cut off on the static crushing effect of columns, eight concrete columns with different strength grades were drilled at the top of the columns along the column height and injected with static crushing agent slurry, and the stirrups were cut off at the side of the holes for four specimens. The sum of the average width of the cracks was used to indicate the crushing effect of the specimens. Test results show that the crushing effect of the specimens decreased with the increase in concrete strength. For the specimens without cutting off stirrups, the decreasing range of the static crushing effect increased with the increase in concrete strength. For the specimens with the stirrups cut off, the decreasing range of the static crushing effect decreased with the increase in concrete strength. Under the conditions that the column section, reinforcement, pore-forming, and static crushing agent slurry injection were all the same, cutting off stirrups could effectively improve the static crushing effect. However, with the increase in concrete strength, the impact of cutting off stirrups on the improvement of the crushing effect decreased gradually. Specimens without cutting off stirrups had densely distributed cracks, and no blocks fell off during the static crushing process, while after removing the protective layer, the inside of the specimens was crumbly; for the specimens with the stirrups cut off, blocks fell off at the corners of the column during the static crushing process.
Keywords:static crushing   concrete column   concrete strength   cut off stirrups   crushing effect
点击此处可从《哈尔滨工业大学学报》浏览原始摘要信息
点击此处可从《哈尔滨工业大学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号