首页 | 本学科首页   官方微博 | 高级检索  
     


Fate of infected and eroded hemodialysis grafts and autogenous fistulas
Authors:B Taylor  RD Sigley  KJ May
Affiliation:Department of Surgery, Swedish Hospital Medical Center, Seattle, Washington.
Abstract:Between 1970 and 1991, we placed 1,090 grafts (bovine and polytetrafluoroethylene) in 1,041 patients and created 1,034 autogenous fistulas in 856 patients for hemodialysis. Subsequent revisions for complications resulted in a total of 3,944 operations performed in patients with grafts and 1,633 operations in patients with autogenous fistulas. A total of 255 infections developed in 158 of the patients with grafts, whereas 8 infections developed in 7 patients with autogenous fistulas. The puncture infection rate was 5%/yr (12%/yr for a second puncture infection). The clean wound infection rate was 3% for grafts and 0.4% for autogenous fistulas. We made an attempt to salvage the graft, usually with a segmental bypass, in 75% of patients with a graft infection. Grafts were salvaged in 80% of patients in whom salvage was attempted (60% of all patients with an infection). The results in the few patients with infected autogenous fistulas were relatively poor.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号