首页 | 本学科首页   官方微博 | 高级检索  
     


Flachdecken in Elementbauweise. Hinweise zum Durchstanznachweis nach DIN 1045‐1
Authors:Johannes Furche  Ulrich Bauermeister
Abstract:Flat Slabs built with Semi‐Precast Elements. Advices to Punching Shear Verification according DIN 1045‐1 Flat slabs are increasingly built with precast slabs and insitu topping. The bearing behaviour of these semi‐precast slabs with lattice girders is similar to cast in one concrete slabs. In principle this is also applied for areas where punching failure is endangered. This was shown in full‐scale tests, which were taken as the basis for derivation of design rules. However during design of semi‐precast slabs some specific items have to be considered. The revision of technical approvals for punching shear reinforcements to the new German design standard for concrete and reinforced concrete DIN 1045‐1 took place during the introduction of new punching shear reinforcement for semi‐precast elements. The required verification of punching shear in element slabs are arranged and explained for different types of punching shear reinforcement.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏