摘    要:对500KV变电所2种安装形式的电容式电压互感器,不拆线预试进行了分析, 特别坚线路侧CVT不拆线对测试的影响作了探讨。

关 键 词:CVT 预试方法 电压互感器 高压引线 变电所

Discussions on Preventive Test of 500 kV Capacitive Voltage Transformer without Disconnecting High Tension Leads
Zhao Jingwu,Li Honglin. Discussions on Preventive Test of 500 kV Capacitive Voltage Transformer without Disconnecting High Tension Leads[J]. Hebei Electric Power, 1999, 18(5): 8-11
Authors:Zhao Jingwu  Li Honglin
Abstract:This paper analyzes the preventive test of two installations of capacitive voltage transformers (CVT) in 500 kV substation.It also analyzes the impact to the test results without disconnecting the high tension leads,especially for the CVT installed on the line side.