首页 | 本学科首页   官方微博 | 高级检索  
     

基于R124-DMAC为工质对的余热吸收式制冷
引用本文:李星,徐士鸣,李见波.基于R124-DMAC为工质对的余热吸收式制冷[J].化工学报,2015,66(5):1883-1890.
作者姓名:李星  徐士鸣  李见波
作者单位:1.大连理工大学能源与动力学院, 辽宁 大连 116024;2.山东科技大学机械电子工程学院, 山东 青岛 266590
基金项目:国家自然科学基金项目(61076022);沈鼓-大工重大科技发展基金。@@@@supported by the National Natural Science Foundation of China,the National Science and Technology Major Project of Shenyang Blower Works Group Corporation-Dalian University of Technology
摘    要:设计并搭建了制冷量为3 kW、以R124-DMAC为工质、采用电热高温空气模拟发动机排气废热的空冷鼓泡吸收制冷实验系统,通过改变热空气进口温度、冷冻水温度和浓溶泵流率测试系统工作参数的变化趋势。实验结果表明,当发生器稀溶液出口温度约为100℃时,蒸发温度为-4℃,系统COP值最大可达到约0.54,而且实验系统稳定性较好;影响系统制冷量和COP值的主要参数是热空气进口温度和冷冻水温度;当蒸发温度低于5℃时,为了提高制冷效果需考虑设置精馏装置。

关 键 词:汽车空调  实验验证  废热  传热  鼓泡吸收  多头螺旋盘管发生器  汽液平衡  热力学  
收稿时间:2014-09-01
修稿时间:2015-01-24

Absorption refrigeration cycle driven by waste heat using R124-DMAC as working fluids
LI Xing,XU Shiming,LI Jianbo.Absorption refrigeration cycle driven by waste heat using R124-DMAC as working fluids[J].Journal of Chemical Industry and Engineering(China),2015,66(5):1883-1890.
Authors:LI Xing  XU Shiming  LI Jianbo
Affiliation:1.School of Energy and Power Engineering, Dalian University of Technology, Dalian 116024, Liaoning, China;2.School of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, Shandong, China
Abstract:Energy saving and emission reduction technologies for vehicles have been paid more attention in recent years, and it is necessary to investigate how to efficiently recover and utilize the waste heat from vehicle engines to drive automotive air conditioning system. Based on that, a full air-cooled bubble absorption refrigeration test system with 3 kW cooling capacity driven by waste heat, using R124-DMAC as working fluids was designed and built. In the system, engine exhaust gas was simulated by heated air. Operating parameters were tested through changing heat source temperature, chilled water temperature and pump flow rate. The maximum COP of the system could reach 0.54 under the condition of generator temperature 100℃ and evaporating temperature -4℃. Heat source and chilled water temperatures had an important effect on cooling capacity and COP, and this system had good stability. However when evaporating temperature was below 5℃, a rectification unit should be considered in order to improve cooling effects. Additionally, this experiment proved that the air-cooled bubble absorber worked well, providing theoretical support for the refrigeration system driven by waste heat in vehicle air conditioning.
Keywords:vehicle air conditioning  experimental validation  waste heat  heat transfer  bubble absorption  multi-thread spiral coil generator  vapor liquid equilibria  thermodynamics
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《化工学报》浏览原始摘要信息
点击此处可从《化工学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号