摘    要:为了测试和评价一体化监控系统高级应用,特别针对智能告警,在一体化监控系统智能告警注入测试系统中,设计了一套完整的测试用例。通过分析某一故障判别逻辑,形成故障信号的排序原则及故障信号序列模板,按照电压等级和故障类型等信息,构建完整的正向和反向的故障信号序列模板库。采用故障信号序列模板与实际工程SCD中故障信号自动映射技术,形成了具体故障的测试用例。开发了可视化的故障信号序列模板配置模块及故障信号映射配置模块。故障信号序列模板库丰富和积累了智能告警方向的测试知识库,信号自动映射技术减少了不同工程的测试用例配置工作量,提升了测试配置的效率。

关 键 词:一体化监控系统  智能告警  故障信号序列模板库  自动映射  测试用例
收稿时间:2017/11/1 0:00:00
修稿时间:2017/12/19 0:00:00

Design of test case for injection test system oriented to advanced application of intelligent alarm in integrated monitoring system
ZHANG Pan,GUO Lingxu,CHEN Jian,KANG Ning,MA Minjie and XIONG Jing.Design of test case for injection test system oriented to advanced application of intelligent alarm in integrated monitoring system[J].Power System Protection and Control,2018,46(22):137-142.
Authors:ZHANG Pan  GUO Lingxu  CHEN Jian  KANG Ning  MA Minjie and XIONG Jing
Affiliation:State Grid Tianjin Electric Power Company Research Institute, Tianjin 300384, China,Tianjin Electric Power Company, Tianjin 300384, China,Tianjin Electric Power Company, Tianjin 300384, China,State Grid Tianjin Electric Power Company Research Institute, Tianjin 300384, China,Five-C Smart Power Grid Technology Co., Ltd., Nanjing 211106, China and Faculty of Physics and Electronic Technology, Hubei University, Wuhan 430062, China
Abstract:In order to test and evaluate the advanced application of the integrated monitoring system and focus on intelligent warning, this paper designs a complete set of test cases for integrated monitoring system smart warning infused test system. It forms arrangement principle of breakdown signal and template for faulted signal sequence via identifying the trouble logic. And it establishes a whole template library for the failure signal sequence from positive and negative directions according to voltage class and fault type. Test samples for specific faults are formed by means of adopting fault signal sequence template and auto-mapping techniques applied in practical engineering SCD. It develops a visual breakdown signal sequence template configuration module and fault signal mapping configuration module. The former enriches and stimulates the test knowledge base for intelligent warning and the latter cuts down the workload for engineering test samples, meanwhile, promotes its efficiency. This work is supported by National High-tech R & D Program of China (863 Program) (No. 2014AA052003).
Keywords:integrated monitoring system  intelligent warning  template library for trouble signal sequence  auto-mapping  test case
本文献已被 CNKI 等数据库收录!
点击此处可从《电力系统保护与控制》浏览原始摘要信息
点击此处可从《电力系统保护与控制》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号