首页 | 本学科首页   官方微博 | 高级检索  
     

CO2再生塔底部塔盘破坏原因分析
引用本文:李国政 盛展武. CO2再生塔底部塔盘破坏原因分析[J]. 大氮肥, 1994, 17(2): 119-122
作者姓名:李国政 盛展武
作者单位:大连理工大学
摘    要:某引进大型化肥装置中CO_2再生塔在初次开车过程中,其底部塔盘发生了严重的挠曲破坏,紧固在支承环上的钩头螺栓,有一半被拉脱。对该事故的原因进行了分析、计算和论证,指出了事故发生的原因,并提出了有关建议以避免类似的事故再次发生。

关 键 词:再生塔 塔盘 合成氨生产 损坏

Reasons for the Breakdown of Bottom Tray of CO_2 generator
Li Guozheng Sheng Zhanwu. Reasons for the Breakdown of Bottom Tray of CO_2 generator[J]. Large Scale Nitrogenous Fertilizer Industry, 1994, 17(2): 119-122
Authors:Li Guozheng Sheng Zhanwu
Abstract:uring the first time commissioning of an imported large-scale chemical fertilizer plant,the bottom tray of CO_2 re-generator was seriously curved,wherein nearly half of the lock bolts connected with the support ring were pulled away from it.Reasons for the breakdown are found by means of analysis calculation,demonstration,and suggestion are made to prevent similar breakdowns from reoccurring.
Keywords:CO_2 regeneration  bottom tray  breakdown  
本文献已被 CNKI 维普 等数据库收录!