首页 | 本学科首页   官方微博 | 高级检索  
     

220kV变电站全站失压事故分析
引用本文:张薇薇. 220kV变电站全站失压事故分析[J]. 贵州电力技术, 2011, 0(10): 48-50
作者姓名:张薇薇
作者单位:贵阳供电局,贵州贵阳550002
摘    要:针对一起220kV变电站全站失压事故,对其事故原因的进行了深入研究。提出并逐一分析了三种220kV终端单线变侧快速解列小电源的技术措施.同时结合本单位的实际情况进行了实施,并获得了良好的效果。

关 键 词:全站失压  小电源  解列  实施

Reflection on an accident of total voltage loss in 220 kV substation
Zhang Weiwei. Reflection on an accident of total voltage loss in 220 kV substation[J]. Guizhou Electric Power Technology, 2011, 0(10): 48-50
Authors:Zhang Weiwei
Affiliation:Zhang Weiwei (Guiyang Power Supply Bureau, Guiyang 550002 Guizhou, China)
Abstract:Considering an accident of total voltage loss in a 220 kV substation, the paper digged into the cause of it, and put forward and analysed separately three technical measures of small power source quick separation at 220 kV terminal for singlet line and variable side. Carried out it basing on practical situation, and obtained good marking effect.
Keywords:total vo]tage loss  small power source  separation  carry out