Abstract:This paper presents a new nonintrusive appliance load monitoring technique based on integer programming. Nonintrusive appliance load monitoring is the problem of identifying the operating conditions of electric appliances in a house by observing only the overall load current and voltage. Since the overall load current is expressed as a superposition of the currents of the operating appliances, the monitoring problem can be formulated as an integer quadratic programming problem by expressing the operating conditions as integer variables. This problem is solvable with a sufficiently small computational burden thanks to the recent development of commercial software. The proposed method does not require relearning even when a new appliance is installed in the house. Furthermore, the proposed formulation is applicable to cases in which some appliance has multiple modes, and cases in which some appliances of the same type are operating simultaneously. The usefulness of the proposed technique is verified by experimental results. © 2010 Wiley Periodicals, Inc. Electr Eng Jpn, 174(2): 18–25, 2011; Published online in Wiley Online Library ( wileyonlinelibrary.com ). DOI 10.1002/eej.21040
Keywords:nonintrusive load monitoring  electric appliance  integer programming