首页 | 本学科首页   官方微博 | 高级检索  
     

前脸墙水包的设置对能耗的影响
引用本文:曹宁宁,方将祥,王海全,李军.前脸墙水包的设置对能耗的影响[J].玻璃,2012,39(4):7-9.
作者姓名:曹宁宁  方将祥  王海全  李军
作者单位:华尔润玻璃产业股份有限公司,张家港市,215625;华尔润玻璃产业股份有限公司,张家港市,215625;华尔润玻璃产业股份有限公司,张家港市,215625;华尔润玻璃产业股份有限公司,张家港市,215625
摘    要:大型浮法玻璃熔窑前脸水包虽然能够起到保护L型吊墙的作用,但会带走投料口的热量,给生产带来不利影响,采用挡焰砖的方案,可减少热损失,对生产、质量的控制较为有利。

关 键 词:熔窑  L型吊墙  前脸墙水包  对开式水包结构  挡焰砖

Discussion on The Effect of Cooling Water of The Gable Wall of L-shape Hanging Wall on Energy Consumption
Cao Ningning,Fang Jiangxiang,Wang Haiquan,Li Jun.Discussion on The Effect of Cooling Water of The Gable Wall of L-shape Hanging Wall on Energy Consumption[J].Class,2012,39(4):7-9.
Authors:Cao Ningning  Fang Jiangxiang  Wang Haiquan  Li Jun
Affiliation:(Farun glass industry Co.,Ltd.,Zhangjiagang 215625)
Abstract:The cooling water package on gable wall of large scale glass furnace can draw off heat from the doghouse although it safeguards the L-shape hanging wall,which have adverse effect on glass melting and leads increase in cost.To avoid this disadvantage the scheme of flame-stop block was presented after related persons discussion.The setting of flame-stop block is beneficial to cost control.
Keywords:furnace  L-shape hanging wall  split structure of water package  flame-stop block