首页 | 本学科首页   官方微博 | 高级检索  
     

精密视觉印刷设备的自标定
引用本文:梁经伦,陈家钊,莫景会,邝泳聪,张宪民.精密视觉印刷设备的自标定[J].光学精密工程,2013,21(2):522-530.
作者姓名:梁经伦  陈家钊  莫景会  邝泳聪  张宪民
作者单位:华南理工大学广东省精密装备与制造技术重点实验室,广东广州,510640
基金项目:国家863高技术研究发展计划资助项目(No.2012AA050302); 粤港关键领域重点突破项目(东莞专项 2012205122); 国家杰出青年科学基金资助项目(No.50825504)
摘    要:为了提高全自动视觉印刷设备的精度,提出了一种简易、有效标定基于三自由度平面并联调整台的视觉丝网印刷设备的算法。首先,分析和标定了视觉测量系统,并通过激光干涉仪验证了结果的准确性。然后,分析了三自由度平面并联调整台的几何参数误差;基于印刷设备自身的视觉测量系统,分步标定了并联平台的动平台坐标系、传动比误差和仅需的部分几何误差源。提出了一种满足全姿态且适应不同制程的三角形面姿态插值方法和纠偏调整算法,从而避免了较为复杂的几何全参数辨识,降低了对调试人员的技术要求。实验结果表明:在并联调整台工作空间内,标定后的最大位置误差从标定前的161.6 μm下降为12.3 μm,最大姿态误差从标定前的2.232″下降为0.720″,基本满足印刷设备对精度的要求。

关 键 词:印刷设备  机器视觉  并联平台  运动学标定  定位精度
收稿时间:2012-11-13
修稿时间:2013-01-01

Self-alibration of precise vision-based printing equipment
LIANG Jing-lun , CHEN Jia-zhao , Mo Jing-hui , KUANG Yong-cong , ZHANG Xian-min.Self-alibration of precise vision-based printing equipment[J].Optics and Precision Engineering,2013,21(2):522-530.
Authors:LIANG Jing-lun  CHEN Jia-zhao  Mo Jing-hui  KUANG Yong-cong  ZHANG Xian-min
Affiliation:Key Laboratory of Precision Equipment and Manufacturing Technology of Guangdong Province, South China University of Technology
Abstract:To improve the precise of all automatic printing equipment, a simple and effective calibration method was proposed to calibrate the screen printing equipment based on a novel three-degree-of-freedom (3-DOF) planar parallel stage. Firstly, a vision-based measuring system was analyzed and calibrated, and its measurement accuracy was also evaluated by a laser interferometer. Then, the geometric errors of the 3-DOF planar parallel stage was analyzed and the frame of the parallel stage's movable platform, screw lead errors and some geometric errors were identified in steps based on a vision-based measuring system in the equipment. Furthermore, the orientation interpolation and alignment methods using a triangular area to position the alignment point were presented to satisfy the need for different product processes in the whole workspace. For the processing mentioned above, this calibration method can calibrate the equipment itself automatically without complicated identification for all geometric errors and the need for any background in parallel robot calibration. Experimental results after calibration show that the maximum position and orientation errors inside the workspace have been reduced from 161.6 μm and 2.232″ to 12.3 μm and 0.720″, respectively, which satisfies the equipment requirement for high accuracy.
Keywords:printing equipment  machine vision  parallel stage  kinematic calibration  position accuracy
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《光学精密工程》浏览原始摘要信息
点击此处可从《光学精密工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号