摘    要:某300 MW四角切圆燃烧锅炉进行低NOx燃烧器和分级燃烧改造后,为了提高锅炉运行的稳定性和经济性,对其进行燃烧调整试验。试验结果表明,分级燃烧可以降低NOx排放水平,但同时会降低锅炉效率。

关 键 词:低NOx  燃烧调整  分级燃烧  锅炉效率

Combustion adjustment after low NO x emission reduction transformation for 300 MW tangentially-fired boiler
WANG Dun-dun,LI Wen-jun.Combustion adjustment after low NO x emission reduction transformation for 300 MW tangentially-fired boiler[J].Hunan Electric Power,2013(6):58-60.
Authors:WANG Dun-dun  LI Wen-jun
Affiliation:( State Grid Hunan Electric Power Corporation Research Institute, Changsha 410007, China )
Abstract:The combustion adjustment test was conducted on a certain 300 MW tangentially fired boiler after low NOx burners and staged combustion transformation in order to improve the stability and economy of the boiler. The results show that staged combustion can reduce NOx emission levels but at the same time it will reduce boiler efficiency .
Keywords:low NOx  combustion adjustment  staged combustion  boiler efficiency